-
Download Miscellaneous Devices Intlib Libraries카테고리 없음 2020. 3. 16. 12:41
Applied Parameters: LibReference=Res2 Library=Miscellaneous Devices.IntLib ModelType=SIM ModelParameterName0=Value ModelParameterValue0=1K Orientation=1 SummaryThis command is used to place a 1K resistor component - Res2, from the Miscellaneous Devices.IntLib - onto the current document. AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor. Applied Parameters: LibReference=Res2 Library=Miscellaneous Devices.IntLib ModelType=SIM ModelParameterName0=Value ModelParameterValue0=4K7 Orientation=1 SummaryThis command is used to place a 4K7 resistor component - Res2, from the Miscellaneous Devices.IntLib - onto the current document.
AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor. Applied Parameters: LibReference=Res2 Library=Miscellaneous Devices.IntLib ModelType=SIM ModelParameterName0=Value ModelParameterValue0=10K Orientation=1 SummaryThis command is used to place a 10K resistor component - Res2, from the Miscellaneous Devices.IntLib - onto the current document. AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor. Applied Parameters: LibReference=Res2 Library=Miscellaneous Devices.IntLib ModelType=SIM ModelParameterName0=Value ModelParameterValue0=47K Orientation=1 SummaryThis command is used to place a 47K resistor component - Res2, from the Miscellaneous Devices.IntLib - onto the current document. AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor. Applied Parameters: LibReference=Res2 Library=Miscellaneous Devices.IntLib ModelType=SIM ModelParameterName0=Value ModelParameterValue0=100K Orientation=1 SummaryThis command is used to place a 100K resistor component - Res2, from the Miscellaneous Devices.IntLib - onto the current document.
AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor. Applied Parameters: LibReference=CAP Library=Miscellaneous Devices.IntLib ModelType=SIM ModelParameterName0=Value ModelParameterValue0=0.01uF Orientation=1 SummaryThis command is used to place a 0.01uF capacitor component - CAP, from the Miscellaneous Devices.IntLib - onto the current document. AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor.
Applied Parameters: LibReference=CAP Library=Miscellaneous Devices.IntLib ModelType=SIM ModelParameterName0=Value ModelParameterValue0=0.1uF Orientation=1 SummaryThis command is used to place a 0.1uF capacitor component - CAP, from the Miscellaneous Devices.IntLib - onto the current document. AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor. Applied Parameters: LibReference=CAP POL1 Library=Miscellaneous Devices.IntLib ModelType=SIM ModelParameterName0=Value ModelParameterValue0=1uF Orientation=1 SummaryThis command is used to place a 1uF polarized capacitor component - CAP POL1, from the Miscellaneous Devices.IntLib - onto the current document. AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor.
Applied Parameters: LibReference=CAP POL1 Library=Miscellaneous Devices.IntLib ModelType=SIM ModelParameterName0=Value ModelParameterValue0=2.2uF Orientation=1 SummaryThis command is used to place a 2.2uF polarized capacitor component - CAP POL1, from the Miscellaneous Devices.IntLib - onto the current document. AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor. Applied Parameters: LibReference=CAP POL1 Library=Miscellaneous Devices.IntLib ModelType=SIM ModelParameterName0=Value ModelParameterValue0=10uF Orientation=1 SummaryThis command is used to place a 10uF polarized capacitor component - CAP POL1, from the Miscellaneous Devices.IntLib - onto the current document. AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor. Applied Parameters: LibReference=SN74F00D Library=Texas InstrumentsTI Logic Gate 2.IntLib Orientation=0 SummaryThis command is used to place a Quad 2-input positive NAND gate component - SN74F00D, from the TI Logic Gate 2.IntLib - onto the current document.
AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor. Applied Parameters: LibReference=SN74F02D Library=Texas InstrumentsTI Logic Gate 2.IntLib Orientation=0 SummaryThis command is used to place a Quad 2-input positive NOR gate component - SN74F02D, from the TI Logic Gate 2.IntLib - onto the current document. AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor. Applied Parameters: LibReference=SN74F04D Library=Texas InstrumentsTI Logic Gate 2.IntLib Orientation=0 SummaryThis command is used to place a Hex Inverter component - SN74F04D, from the TI Logic Gate 2.IntLib - onto the current document. AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor. Applied Parameters: LibReference=SN74F08D Library=Texas InstrumentsTI Logic Gate 2.IntLib Orientation=0 SummaryThis command is used to place a Quad 2-input positive AND gate component - SN74F08D, from the TI Logic Gate 2.IntLib - onto the current document.
AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor. Applied Parameters: LibReference=SN74F32D Library=Texas InstrumentsTI Logic Gate 2.IntLib Orientation=0 SummaryThis command is used to place a Quad 2-input positive OR gate component - SN74F32D, from the TI Logic Gate 2.IntLib - onto the current document. AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor. Applied Parameters: LibReference=SN74F126D Library=Texas InstrumentsTI Logic Buffer Line Driver.IntLib Orientation=0 SummaryThis command is used to place a Quadruple Bus Buffer Gate with 3-State Outputs component - SN74F126D, from the TI Logic Buffer Line Driver.IntLib - onto the current document. AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor. Applied Parameters: LibReference=SN74F74D Library=Texas InstrumentsTI Logic Flip-Flop.IntLib Orientation=0 SummaryThis command is used to place a Dual Positive-Edge-Triggered D-Type Flip-Flop with Clear and Preset component - SN74F74D, from the TI Logic Flip-Flop.IntLib - onto the current document.
AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor. Applied Parameters: LibReference=SN74F86D Library=Texas InstrumentsTI Logic Gate 2.IntLib Orientation=0 SummaryThis command is used to place a Quad 2-input XOR gate component - SN74F86D, from the TI Logic Gate 2.IntLib - onto the current document. AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor.
Applied Parameters: LibReference=SN74F138D Library=Texas InstrumentsTI Logic Decoder Demux.IntLib Orientation=0 SummaryThis command is used to place a 3-Line to 8-Line Decoder / Demultiplexer component - SN74F138D, from the TI Logic Decoder Demux.IntLib - onto the current document. AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor. Applied Parameters: LibReference=SN74F245DW Library=Texas InstrumentsTI Interface 8-Bit Line Transceiver.IntLib Orientation=0 SummaryThis command is used to place an Octal Bus Transceiver with 3-State Outputs component - SN74F245DW, from the TI Interface 8-Bit Line Transceiver.IntLib - onto the current document.
On Semi Altium Library
AccessThis command is accessed from the Schematic Editor by clicking the button on the Digital Devices drop-down ( ) of the Utilities toolbar.UseAfter launching the command, the cursor will change to a cross-hair and an outline of the component will appear floating on the cursor.